5. If you are instructed to return the microprocessor, follow all packaging
instructions and use any packaging materials that are supplied to you for
shipping.
6. To complete the removal procedure, go to “Completing the parts replacement”
on page 87.
Installing the microprocessor
Attention
Do not open your server or attempt any repair before reading and understanding the Safety
Information and the Warranty and Support Information on the ThinkServer Documentation DVD
that comes with your product, and “Guidelines” on page 37. To obtain a copy of the
publications, go to:
http://www.lenovo.com/support
This section provides instructions on how to install the microprocessor.
CAUTION:
The heat sink and microprocessor might be very hot. Turn off the server and
wait three to five minutes to let the server cool before removing the server cover.
Note: When you need to install a second microprocessor, first remove the dual
heat sink and then remove excess grease from the first microprocessor and
the microprocessor socket area. Make sure the microprocessor and socket
area are clean of grease. Use the new heat sink that comes with the second
microprocessor option kit and dispose of the old one. The new heat sink has
grease already applied for both the first and second microprocessors.
For optimal performance, follow these microprocessor installation rules:
1. When two microprocessors are installed, both must have the same core voltage
and core speed.
2. When only one microprocessor is installed, it must be in the socket labeled
CPU0. The other socket must be kept empty.
3. Always install the microprocessor first into the CPU0 socket, and then install
another microprocessor into the CPU1 socket if you want to install two
microprocessors.
To install the microprocessor, do the following:
1. Remove all media from the drives and turn off all attached devices and the
server. Then, disconnect all power cords from electrical outlets and disconnect
all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 42.
3. Remove the heat sink assembly. See “Removing the heat sink assembly” on
page 69.
Chapter 5. Installing, removing, or replacing hardware 73