CAUTION:
The heat sink and microprocessor might be very hot. Turn off the server and
wait three to five minutes to let the server cool before removing the server cover.
To install the heat sink assembly, do the following:
1. Remove all media from the drives and turn off all attached devices and the
server. Then, disconnect all power cords from electrical outlets and disconnect
all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 42.
3. Position the heat sink assembly in place by aligning the retaining screws on the
heat sink assembly with the corresponding holes in the system board. Then,
tighten the eight screws following the numerical sequence as shown below to
secure the heat sink assembly on the system board.
1 - 8 Screws
9 Air flow
10 Indicates the front of the chassis
4. To complete the installation, go to “Completing the parts replacement” on page
87.
Figure 33. Installing the heat sink assembly
Chapter 5. Installing, removing, or replacing hardware 71