Lenovo Computer Monitor 7098 Manuel d'utilisateur Page 74

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 798
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 73
Diagnostic Error Code FRU/Action
020-199-XXX
PCI test failed, cause unknown
1. Go to “Undetermined problems” on page
82
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Replace component under function test
020-262-XXX
PCI system error
1. PCI card
2. Riser card, if installed
3. System board
025-000-XXX
IDE interface Test Passed
No action
025-00X-XXX
025-01X-XXX
IDE interface failure
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
025-027-XXX
IDE interface Configuration/Setup error
1. IDE signal cable
2. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
3. Reseat IDE signal cable
4. IDE device
5. System board
025-02X-XXX
025-03X-XXX
025-04X-XXX
IDE Interface failure
1. IDE signal cable
2. Check power supply
3. Reseat IDE signal cable
4. IDE device
5. System board
025-195-XXX
IDE interface Test aborted by user
Information only
Re-start the test, if necessary
025-196-XXX
IDE interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
025-197-XXX
IDE interface test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
68 Hardware Maintenance Manual
Vue de la page 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 797 798

Commentaires sur ces manuels

Pas de commentaire